CM-200GE/CM-200GE-RA/CB-200GE/CB-200GE-RA
- 38 -
TriggerActivation
This can set how the trigger is activated.
RisingEdge: The trigger is effective at the rising edge of the pulse.
FallingEdge: The trigger is effective at the falling edge of the pulse.
ExposureMode
This can select the exposure mode.
Timed: The exposure is set in units of
μ
seconds or lines.
TriggerWidth: The exposure is the same as the trigger width.
The CM-200GE and CB-200GE series have a JAI Acquisition and Trigger Control function which is
the same as used for previous models and includes 7 types of exposure modes.
Acquisition and Trigger Control and JAI Acquisition and Trigger Control are linked to each other
and if the one is set, the setting parameters are reflected in the other.
The following is an example: when JAI Acquisition and Trigger Control is set at EPS, TriggerMode is
automatically set ON and ExposureMode is set to Timed.