CM-200 MCL / CB-200 MCL
Vertical timing
Vertical Video Timing
V Binning
Frame rate : 627L 44.492 fps
LVAL
FVAL
DVAL
DATA
EEN
XEEN
CCD Exposure
Valid data
OB
OB
OB
1+2 3+4
5L
3L
618L
1L
1233+1234 1235+1236
Fig.18. Vertical Timing for Vertical Binning
6.3.
Operation Modes
This camera can operate in 3 primary modes.
1.
TR=0
Continuous Mode.
Pre-selected exposure.
2.
TR=1
Pre-select Mode.
Pre-selected exposure.
3.
TR=2
Pulse Width Control Mode.
Pulse width controlled exposure.
6.3.1.
Continuous operation
For applications not requiring asynchronous external trigger, but should run in continuous
operation, this mode is used.
For timing details, refer to fig. 13 through fig. 18.
To use this mode:
Set function:
Trigger mode to “Continuous”.
TR=0
Scanning
SC=0
through
4
V
Binning
VB=0,
VB=1
Shutter mode pre-set or programmable
SM=0 SM=1
Shutter speed
SH=0 to 9
Programmable exp.
PE=2 to 1252
Other functions and settings
6.3.2.
Edge Pre-select Trigger Mode
An external trigger pulse initiates the capture, and the exposure time (accumulation time) is
defined by the SH or PE command.
The resulting video signal will start to be read out after the selected shutter time.
For timing details, refer to fig. 13 through fig. 18 and fig. 19 & 20.