CM-200 MCL / CB-200 MCL
LVAL a-SYNC mode timing
4. 86
μ
s ±
1
μ
s
1L(Min.)
CCD exposure
Trig
2L to 3L
EEN
XEEN
FVAL
Exposure
1L
Trigger input during FVAL LOW period
LVAL a-SYNC mode setting
Fig.22. Pulse Width Control LVAL a-Synchronous
6.4.
Mode and function matrix.
The following table shows which functions will work in the different modes for CM-200MCL / CB-
200MCL.
Func.
Shutter
Trigger Mode
Pre-select
Accumulation
Iris
Partial
V Binning
Programmabl
e
scan
LVAL sync /
Video
a-sync
out
Continuos
TR=0
Yes Yes Yes Yes - Yes
Pre-select
TR=1
Yes Yes Yes Yes Yes -
Pulse Width TR=2
-
Yes
Yes
Yes
-
Fig. 23. Mode and function matrix.