Also, check the “Error Status” register. If there is a connection error, LS1_ERR or LS2_ERR is set. If a
light sensor is not required for your application, set the “Camera ADR Control” register to “Manual.”
3.3.2
Flash Nighttime Light Control
The strobe and continuous nighttime light can be manually turned on and off. Set “Flash
Auto/Manual” and “Night light Control” registers to Manual OFF or ON.
Generate an Ethernet trigger or input TTL trigger to see Flash. The “Live” or “Snap” button does
not generate Flash, because they are independent from normal trigger operation.
Normally, Flash and Night Light are controlled by ADR and a light sensor. To take advantage of this
feature, connect to the light sensor. Set the “Flash Auto/Manual” and “Night Light Control”
registers as shown below.
In this setting, in the evening when light sensor reading drops below 12, Flash and Night Light are
turned on. And in the morning when the light sensor reading rises above 17, Flash and Night Light
are turned off.