GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0)
Preparation
- 29 -
Configure Exposure and External Trigger Settings
Configure settings related to exposure control methods and trigger control. The factory settings are as
follows. Change settings as necessary, according to the intended purpose or application.
Factory Default Values
Item
Default
Trigger Selector
Frame Start
- Trigger Mode
Off
- Trigger Source
Line 5 - Optical In 1
- Trigger Activation
Rising Edge
Exposure Mode
Timed
Exposure Time
GO-2400MC-PGE: 18000 (μs)
GO-2401MC-PGE: 24087 (μs)
Exposure Auto *
Off
Note:
*This item is only enabled when
Exposure Mode
is set to
Timed
.
Cautions
:
l
When
Exposure Mode
is set to
Off
,
Trigger Mode
cannot be set to
On
. Other settings may
also be restricted depending on the exposure mode, so be sure to set the exposure mode
before configuring the trigger settings.
l
Adjusting Packet Size
: With
Trigger Mode
set to
Off
and
Exposure Mode
set to
Continuous
, clicking the
Start Acquisition
button should produce a live image. If, however,
you can only see a black screen, it may be the result of the packet size setting in the camera
being larger than the packet size setting in the GigE NIC or switch. To correct the problem,
you can either reduce the Packet Size setting to a value less than 1500 in the eBUS Player
for JAI (under Transport Layer Control / Stream Channel Selector, or set your NIC or switch
to support “Jumbo Frames.” This setting is typically found in the Advanced Adapter Settings
for the NIC or switch which can be accessed through the Device Manager on your PC.