GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0)
Main Functions
- 43 -
Source
Signal
Output destination
Trigger Selector
Line Selector
Pulse Generator
Selector
Acquisition
Start
Acquisition
Stop
Frame
Start
Transfer
Start
Line
2
Line
3
Time
Stamp
Reset
NAND
1 In 1
NAND
1 In 2
NAND
2 In 1
NAND
2 In 2
Pulse Generator
0
Frame Active
✓
✓
✓
✓
✓
✓
✓
✓
Acquisition
Trigger Wait
✓
✓
✓
✓
✓
✓
✓
✓
Trigger Source
Line Source
Pulse Generator
Clear Source
✓
: Supported
Acquisition Control
Related Setting Items:
Perform operations and configure settings related to image acquisition in Acquisition Control. The
following acquisition modes are available on the camera.
Acquisition
Mode
Description
Single Frame
Acquire a single frame when the
Acquisition Start
command is executed.
Multi Frame
Acquire the number of frames specified in Acquisition Frame Count when the
Acquisition
Start
command is executed.
Continuous
Acquire images continuously until the
Acquisition Stop
command is executed.
Change the Frame Rate
When Trigger Mode is disabled, you can change the frame rate in Acquisition Frame Rate.
Notes:
l
The shortest frame period varies depending on the ROI, Pixel Format, and Binning Mode
selected. The longest frame period is 0.125 Hz (8 sec.).
l
When Trigger Mode is enabled, the Acquisition Frame Rate setting is disabled.