GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0)
Main Functions
- 44 -
Maximum Frame Rate
The maximum frame rate is as follows depending on the sensor’s scanning range and the GigE
bandwidth.
Note:
The Frame Rate Calculator, which calculates the maximum frame rate, is available for
download from the product page on the JAI website (
).
Maximum Frame Rate Period Formula
During continuous operation (Frame Start trigger is Off or Exposure Mode is Off)
l
Maximum frame rate of sensor output
SensorFR = 1/((He 40)×Hperiod)
l
Maximum frame rate of GigE output bandwidth
InterfaceFR = 920 × 1000000/(Height_g × Width_g × Pack value)
l
Maximum frame rate
FR_Cont = Min (SensorFR, InterfaceFR)
When Frame Start trigger is On and Trigger OverLap is Off
l
Maximum frame rate of sensor output
Sensor FR = 1 / {H Period × ( 40)}
l
Maximum frame rate by interface