GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0)
Main Functions
- 48 -
Trigger Control
Related Setting Items:
The camera allows the following controls to be performed via external trigger signals.
Trigger Selector
Description
FrameStart
Start exposure in response to the external trigger signal input. Select this to perform
exposure control using external triggers.
AcquisitionStart
Start image acquisition in response to the external trigger signal input.
AcquisitionEnd
Stop image acquisition in response to the external trigger signal input.
AcquisitionTransferStart
Output acquired images at a specified timing in response to an external trigger
signal input. (Up to 7 frames for 8-bit, and up to 3 frames for 10-/12-bit.)
Note:
The settings for exposure control and triggers are related to each other. Be sure to
configure the settings described in “
Configure Exposure and External Trigger Settings
”.
Shortest Repetition Period for Triggers
The reciprocal of the maximum frame rate is the time required to output one frame. The shortest
repetition periods for triggers cannot be lower than that value.
Scanning Range
Shortest Period of Trigger
8 bit (ms)
10 bit/12 bit Packed (ms)
10 bit/12 bit (ms)
GO-2400-
PGE
GO-2401-
PGE
GO-2400-
PGE
GO-2401-
PGE
GO-2400-
PGE
GO-2401-
PGE
Full
20.472
24.360
30.707
30.707
40.943
40.943
ROI 2/3 (Height=810)
13.637
16.486
20.608
20.608
27.273
27.273
ROI 1/2 (Height=608)
10.236
12.569
15.711
15.711
20.472
20.472
ROI 1/4 (Height=304)
5.118
6.673
8.341
8.341
10.236
10.236
ROI 1/8 (Height=152)
2.559
3.725
4.656
4.656
5.118
5.118
Binning Vertical 2
(Monochrome models
only)
15.632
24.360
30.450
30.450
30.450
30.450
The above table indicates the shortest trigger periods for when Trigger OverLap is set to Readout.
When Trigger OverLap is set to Off, the exposure time is added to the period.