GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0)
Settings List
- 79 -
AcquisitionControl
Configure image acquisition settings.
Note:
Settings that can only be configured when image acquisition on the camera is stopped.
Acquisition
Control Item
Setting
Range
Default
Description
Acquisition Mode
Single Frame
Multi Frame
Continuous
Continuous
Select the image acquisition mode.
Related Topic:
Acquisition Start
-
-
Start image acquisition.
Acquisition Stop
-
-
Stop image acquisition.
Acquisition Frame
Count
1 ~ 255
1
In
Multi Frame
mode, set the number of frames to acquire.
Acquisition Frame
Rate (Hz)
0.125 ~
48.8496
48.8496
Set the frame rate as a frequency. (unit: Hz) The maximum value varies
depending on the TapGeometory and ROI settings.
Trigger Selector
Acquisition
Start
Acquisition
End
Frame Start
Acquisition
Transfer Start
Frame Start
Select the trigger operation.
Related Topic:
Trigger Mode
Off
On
Off
Select the trigger mode.
Trigger Software
-
-
Execute a software trigger.
Trigger Source
Low
High
Software
Pulse
Generator0
User Output
0
User Output
1
Action 1
Action 2
Line 5 -
Optical In 1
Nand0 Out
Nand1 Out
Line 5 - Optical In
1
Select the trigger signal source.