JAICustomControlMultiROI
Related Topic:
Configure settings for JAI sensor multi ROI.
Notes:
l
This function is supported only on GO-2400M-PGE and GO-2400C-PGE.
l
Settings that can only be configured when image acquisition on the camera is stopped.
Multi ROI Item
Setting
Range
Default
Description
Sensor Multi Roi Enable
False
True
False
Enable/disable sensor Multi Roi.
Sensor Multi Roi Index
Index 1 ~ 4
Index 1
Select the index for the sensor Multi Roi mode.
Sensor Multi Roi Width
16 ~ 1936 / 16
steps
1936
Set the width for the selected sensor Multi Roi index.
Sensor Multi Roi Height
2 ~ 1216 / 2 steps 1216
Set the height for the selected sensor Multi Roi index.
Sensor Multi Roi Offset X
0 ~ 1920 * / 16
steps
*Max: (1936 -
Width)
0
Set the horizontal offset for the selected sensor Multi Roi index.
Sensor Multi Roi Offset Y
0 ~ 1214 / 2 steps
*Max: (1216 -
Width)
0
Set the vertical offset for the selected sensor Multi Roi index.
Sensor Multi Roi Horizontal Enable
Off
On
Off
Enable/disable Width/Offset X for the selected sensor Multi Roi
index.
Sensor Multi Roi Vertical Enable
Off
On
Off
Enable/disable Height/Offset Y for the selected sensor Multi Roi
index.