GO-2400MC-PGE | GO-2401MC-PGE | User Manual (Ver. 3.0)
Settings List
- 85 -
Digital IO Control
Related Topic:
GPIO (Digital Input/Output Settings)
Configure settings for digital input/output.
Digital IO Control
Item
Setting
Range
Default
Description
Line Selector
Line2 - Opt Out
Line3 - Opt Out 2
Line5 - Opt In 1
Time Stamp
Reset
NAND Gate 0 In 1
NAND Gate 0 In 2
NAND Gate 1 In 1
NAND Gate 1 In 2
Line2 - Opt
Out
Select the input/output to configure.
LineSource
Low
High
Acquisition
Trigger Wait
Acquisition Active
Frame Trigger
Wait
Frame Active
Exposure Active
FVAL
User Output 0
User Output 1
Line 5 - Optical In
1
Pulse Generator
0
Nand0 Out
Nand1 Out
Low
Select the line source signal for the item selected in Line Selector.
Line Inverter
False
True
False
Enable/disable polarity inversion for the selected input signal or output
signal.
Line Status
False
True
True
Display the status of the input signal or output signal (True: High,
False: Low).
Related Topic:
Line Mode
Input
Output
Output
Display the input/output status (whether it is input or output).