Continuous
In this mode, when the AcquisitionStart command is set, the image is continuously output at the
current frame rate. This is the default setting for this camera.
Normal Continuous Operation
1. AcquisitionStart command is input
2. AcquisitionTriggerWait becomes effective
3. AcquisitionActive becomes “TRUE”
4. Images begin outputting continuously
5. AcquisitionStop command is sent
6. AcquisitionActive becomes “FALSE”. At this moment, the output stops.
However, if AcquisitionStop command is initiated during image output period, AcquisitionActive
becomes “FALSE” (stop capturing) after image output is completed.
Note:
This figure is if the trigger is set to ON, and when the trigger is OFF, FrameActive becomes
True at the same timing of AcquisitionActive.
Forcing Acquisition to Stop
If AcquisitionStop is executed and the video is already output when the camera receives the stop
command, AcquisitionActive becomes False (disabling the capture) after the video output is