GO-5000M-PGE | GO-5000M-PGE-UV | User Manual (Ver. 2.0)
Main Functions
- 63 -
Trigger Width Mode
In this mode, the exposure time is equal to the trigger pulse width. Accordingly, longer exposure times
are supported. Additional settings determine if the trigger pulse can be accepted during the exposure
period.
As the exposure time is shortened against an input trigger width, the input trigger width should be “the
necessary exposure time plus 8.2 μs”.
Primary settings to use this mode
l
Trigger Mode = ON
l
Exposure Mode = Trigger Width
l
Trigger Source: Opt IN (6p connector)
l
Trigger Option: OFF
l
Optical Filter Selector: 10μs
Readout Mode
Minimum Trigger Interval
Full
45.2 ms - 3μs
ROI 2/3 (Height=1365)
30 ms - 3μs
ROI 1/2 (Height=1024)
22.4 ms - 3μs
ROI 1/4 (Height=512)
11.4 ms - 3μs
ROI 1/8 (Height=256)
5.8 ms - 3μs
1/2V Binning
22.4 ms - 3μs
t1
t2
t3
t4
10 μs (Min)
61 μs
53 μs
5L to 6