GO-5000M-PGE | GO-5000M-PGE-UV | User Manual (Ver. 2.0)
Main Functions
- 69 -
Descriptions of Index Table Parameters
Command
Parameter
Description
Sequence ROI Index
Index 1 ~ 10
Select an index to be set
Sequence ROI Frame
Count
1 ~ 255
<Set to each Index>
Set fame number for display per a frame
Sequence ROI Next
Index
Index 1 ~ 10
Off
<Set to each Index>
<Used for Trigger Sequence Mode>
Set the index to be active at the next
Off: Stop a sequence operation at the current index.
Sequence ROI Width
16 ~ 2560*
<Set to each Index>
Set the width value
Sequence ROI Height
1 ~ 2048*
<Set to each Index>
Set the height value
Sequence ROI Offset X
0 ~ 2560*- [Sequence ROI
Width]
<Set to each Index>
Set the offset value.
Sequence ROI Offset Y
0 ~ 2048* – [Sequence ROI
Height]
<Set to each Index>
Set the offset Y.
Sequence ROI Gain
100 ~ 1600
<Set to each index>
Set the gain value.
Sequence ROI
Exposure Time
10 ~ 8000000
<Set to each Index>
Set the exposure time value.
Sequence ROI H
Binning
1, 2, 4 (3 is disabled)
<Set to each Index>
Set the H Binning value.
Sequence ROI V
Binning
1, 2, 4 (3 is disabled)
<Set to each Index>
Set the V Binning value.
Sequence ROI LUT
enable
0 (Disable)
1 (Enable)
<Set to each Index>
Set the disable or enable of LUT. If it is set to enable, the function is selected in the
Sequence LUT mode.
Sequence ROI Black
Level
-256 ~ 255
<Set to each index>
Set the black level value.
Sequence Repetition
1 ~ 255
<For Trigger Sequence Mode>
Set the repeat number of the sequence.
Command Sequence
Index
Index 1 ~ 10
<For Command Sequence Mode> Set the performed index.
Current Sequence
Index
Index 1 ~ 10
<READ only>
Refer to the current Sequence Index.
Sequence LUT Mode
Gamma LUT
Set the function if Sequence ROI LUT is set to enable.
Set the value on Gamma or LUT control.
Sequence Reset
No (EXE command)
Reset the Sequence Index to 0.
At the same time, the Frame Count is also initialized.
Note:
*If the binning mode is used, the maximum value is changed.