GO-5000M-USB-UV User Manual (Ver. 1.1)
Main Functions
- 64 -
Primary settings to use this mode
l
Exposure Mode: Timed
l
Trigger Selector: Frame Start
l
Trigger Mode: ON
l
Trigger Option: RCT
If ALC control is used together with RCT mode, then
l
Exposure auto: Continuous
l
Gain Auto: Continuous
Minimum interval of the trigger
Read Out Mode
Minimum Trigger Interval
Full
16.447 ms
ROI 1/2 (Height=1024)
8.375 ms
ROI 1/4 (Height=512)
4.35 ms
1/2V Binning
8.375 ms
t1
t2
t3
10 μs (Min)
102μs
5L ~ 6L
Notes:
l
The trigger is input through 6P Optical input. Accordingly, the timing will be changed if the
optical filter is set to the other figures.
l
Other timings are internal operating timing of a camera.