ALC Channel Area
Trigger Control
Related Setting Items:
The camera allows the following controls to be performed via external trigger signals.
Trigger Selector
Description
FrameStart
Start exposure in response to the external trigger signal input. Select this to perform
exposure control using external triggers.
AcquisitionStart
Start image acquisition in response to the external trigger signal input.
AcquisitionEnd
Stop image acquisition in response to the external trigger signal input.
AcquisitionTransferStart
Output acquired images at a specified timing in response to an external trigger
signal input. (Up to 7 frames for 8-bit, and up to 3 frames for 10-/12-bit.)
Note:
The settings for exposure control and triggers are related to each other. Be sure to
configure the settings described in “
Configure Exposure and External Trigger Settings
”.