Setting range
Default value
Description
Configure shading correction settings.
Flat Shading
Flat Shading
Select the shading correction method.
Off, User1, User2,
User3
Off
Set the area to which to save shading
correction data.
When this is set to [Off], shading correction
data is not saved.
ー
ー
Execute shading correction.
ー
ー
Display the shading correction results.
Setting range
Default value
Description
Configure counter settings.
(This camera only supports counter functions.)
Counter 0 to 2
ー
Select the counter.
Counter 0 to 2 Event Source
Off,
Frame Trigger,
Frame Start,
Exposure Start,
Frame Transfer End
Off
Assign the counter event signal for which
you want to read the count value to a
dedicated counter, and read the value.
Counter 0 to 2 Event Activation Rising Edge
Falling Edge
ー
Set the count timing.
Counter 0 to 2 Reset
ー
ー
Reset the counter.
Counter 0 to 2 Refresh
ー
ー
Update the count value.
Counter 0 to 2 Value
ー
0
Display the count value.
Counter 0 to 2 Status
ー
Counter Active
Display the counter status.
Setting range
Default value
Description
Configure controling polarization settings.
Raw Image,
Polarize Angle And Degree
Raw Image
Set the video output mode
Setting range
Default value
Description
Configure settings for other JAI functions.
Off, On
Off
Enable/disable VideoProcessBypass mode.
Off
Off
10μs, 100μs, 500μs,
1ms, 5ms, 10ms
10μs
Select the surge protection filter
Normal Mode
Normal Mode
Display the [VideoSendMode].
Item
m) JAI Custom Control Shading
Item
Item
Shading Correction Mode
Video Send Mode
OptIn Filter Selector
VideoProcessBypassMode
Shading Detect Result
Perform Shading Calibration
Shading Mode
Trigger Option
p) JAICustomControlMisc
Item
n) Counter And Timer Control
Counter 0 to 2
o) JAICustomControlPolarized
Polarize Image Selector
—
53
—
GO-5100MP-PGE