— 49 —
GO-5100MP-USB
Setting range
Default value
Description
Configure image capture settings.
Single Frame,
Multi Frame,
Continuous
Countinuous
Select the image capture mode.
ー
ー
Start image capture.
ー
ー
Stop image capture.
1〜255
1
In [MultiFrame] mode, set the number of
frames to capture.
0.125〜74.0192
74.0192
Set the frame rate as a frequency. (unit:
Hz)
The maximum value varies depending on
the PixelFormat and ROI settings.
Acquisition Start,
Acquisition End,
Frame Start,
Acquisition Transfer Start
Frame Start
Select the trigger operation.
Trigger Mode
Off, On
Off
Select the trigger mode.
Trigger Software
ー
ー
Execute a software trigger.
Trigger Source
Low
High
Software
Pulse Generator0
User Output 0
User Output 1
Line5 - Optical In 1
NAND0Out
NAND1Out
Line 5 - Optical In 1
Select the trigger signal source.
Trigger Activation
Rising Edge
Falling Edge
Rising Edge
Select the polarity of the trigger signal
(i.e., location of signal at which trigger is applied).
Trigger Overlap
Off, ReadOut
Off
Select the trigger overlap operation.
Off, Timed,
Trigger Width
Timed
Select the exposure mode.
1 〜
ー
Set the exposure time. The specifiable
range varies depending on the
[StartTriggerMode] and
[PixelFormat] setting.
Off, Continuous
Off
Set whether to enable auto exposure.
Setting range
Default value
Description
Configure analog control settings.
Analog All
Analog All
Select the gain to configure.
Gain
x1.0 〜 x16.0
x1.0
Set the gain value for the gain setting
selected in [GainSelector].
Digital All
Digital All
Select the black level to configure.
Black Level
-133〜255
0
Set the black level value.
Off,
Continuous
Off
Enable/disable gain auto adjustment.
[Once] automatically changes to [Off]
when the signal level converges once.
Item
ExposureAuto
ExposureTime
ExposureMode
Trigger Selector
AcquisitionFrameRate(Hz)
AcquisitionFrameCount
d)
) nalog Control
Gain Selector
GainAuto
Black Level Selector
Acquisition Stop
c)
) cquisition Control
Acquisition Mode
Acquisition Start
Item