— 52 —
GO-5100MP-USB
Setting range
Default value
Description
Configure sequencer settings.
Off, On
Off
Enable(On)/disable(Off) [SequencerMode].
Trigger Sequencer Mode,
Command Sequencer Mode
Trigger Sequencer Mode
Select the sequencer mode.
Off, On
On
Select [On] to change the settings within
the index.
1〜128
1
Select the index number to configure.
Sequencer Frame Number
1〜255
1
Set the number of frames to display for the
selected SequencerIndex.
(Enabled only for TriggerSequencer.)
Sequencer Set Next
0〜128
ー
Set the next index to be displayed for the
selected SequencerIndex.
(Enabled only for TriggerSequencer.)
If 0 is specified, the operation of Sequencer is
stopped.
Sequencer Width
16〜2464
2464
Set the width of the selected
SequencerIndex.
Sequencer Height
1〜2056
2056
Set the height of the selected
SequencerIndex.
Sequencer OffsetX
0 〜 2448
0
Set the horizontal offset value for the
selected SequencerIndex.
Sequencer OffsetY
0 〜 2055
0
Set the vertical offset value for the selected
SequencerIndex.
Sequencer Gain
100〜1600
100
Set the GainAnalogAll value.
Sequencer Exposure Time
1 〜 8000000
ー
Set the exposure time for the selected
SequencerIndex.
Sequencer Black Level
-133〜255
0
Set the BlackLevelDigitalAll for the selected
SequencerIndex.
Sequencer H Binning
1,2
1
Set the H Binning for the selected
SequencerIndex.
Binning Horizontal Mode setting is applied in binning
mode.
Sequencer V Binning
1,2
1
Set the V Binning for the selected
SequencerIndex.
Binning Vertical Mode setting is applied in binning
mode.
1〜255
1
Set the repeat count for the sequencer.
1〜128
1
Displays the sequencer set number.
1〜128
1
Set this to change the SequencerIndex.
(Enabled only for CommandSequencer.)
1〜128
1
Specify the first index number to switch to when
starting [TriggerSequencerMode].
ー
ー
In [TriggerSequencerMode], reset the current index
number to the number configured in
[SequencerSetStart].
Sequencer Configuration Mode
Sequencer Mode Select
Sequencer Mode
Item
Sequencer Set Selector
Sequencer Command Index
Sequencer Set Active
Sequencer Repetition
h)
) equencer Control
Sequencer Reset
Sequencer Set Start