— 34 —
GO-5101M-PMCL / GO-5101C-PMCL
LUT ( Lookup Table)
The LUT function is used to generate a non-linear mapping between signal values captured on the
sensor and those that are output from the camera. You can specify the output curve using 257 setting
points (indexes).
■
To use the LUT function
Configure the settings as follows.
Item
Setting value / selectable range
Description
JAI LUT Mode
LUT
Use LUT.
LUT Selector*
GO-5101M-PMCL:
Mono
GO-5101C-PMCL:
Red,
Green,
Blue
Select the LUT channel to control.
LUT Index
GO-5101M-PMCL: 0 to 256
GO-5101C-PMCL: 0 to 256
Select the LUT index to configure. Indexes represent the
possible pixel values captured on the sensor, from the lowest
value (Index 0) to the highest (Index 256). For example,
Index 0 represents a full black pixel and Index 255
represents a full white pixel.
LUT Value
0 to 4095
Set the LUT output value for the selected index.
* GO-5101C-PMCL only
■
LUT values
LUT values range from 0 at the lowest to 4095 at the highest. Linear interpolation is used to calculate
LUT values between the index points.
4095
Index0
Index1
LUT Value [1]
LUT Value [0]
Index256
Values between points are determined
using the linear interpolation values of
data to the left and right.