GO-5101M-PMCL / GO-5101C-PMCL
Auto gain metering areas (16 areas)
Low
Right
Low
Mid-right
Low
Mid-left
Low
Left
Mid-Low
Mid-left
Mid-High
Mid-left
High
Mid-left
Mid-Low
Left
Mid-High
Left
High
Left
High
Mid-right
Mid-High
Mid-right
Mid-Low
Mid-right
High
Right
Mid-High
Right
Mid-Low
Right
Counter and Timer Control Function (counter support only)
The counter function counts up change points in the camera’s internal signals using the camera’s
internal counter, and reads that information from the host side. This function is useful for verifying error
conditions via the count value using internal camera operations.
Counting is performed at frame trigger, frame start, exposure start, and exposure transfer end, and
by comparing these values, you can determine the internal camera state at which missed triggers will
occur.
■
Counter occurrence diagram
Frame trigger
Frame trigger counter
Set to count 1
Exposure Start
Exposure start counter
Set to count 2
Event occurrence
Event occurrence
Count up
Count up
Count 2
request
Read count
value
Count 1
Request
MCU
HOST
Read count
value
Counter reset
Counter reset
Count 1 reset
Count 2 reset
Note