— 50 —
GO-5101M-PMCL / GO-5101C-PMCL
Item
Setting range
Default value
Description
Pulse Generator Length
1 to 1048575
30000
Set the maximum count-up value as a
clock count.
Pulse Generator Length
(ms)
0.002222 to 2330.166666
66.6667
Set the maximum count-up value in
milliseconds.
This value is calculated using the [Pulse
Generator Length] value as a base.
The setting range varies depending on
the [Clock Pre-scaler] value.
Pulse Generator Frequency
(Hz)
0.429154 to 450000
15
Set the maximum count-up value as a
frequency.
This value is calculated using the [Pulse
Generator Length] value as a base.
Pulse Generator Start Point
0 to 1048574
0
Set the start point of the High interval as a
clock count.
When the counter reaches this value, the
output will be 1.
Pulse Generator Start Point
(ms)
0 to 2330.164444
0
Set the start point of the High interval in
milliseconds.
When the counter reaches this value, the
output will be 1.
The setting range varies depending on
the [Clock Pre-scaler] value.
Pulse Generator End Point
1 to 1048575
15000
Set the end point of the High interval as a
clock count.
Pulse Generator End Point
(ms)
0.002222 to 2330.166666
33.3333
Set the end point of the High interval in
milliseconds.
Pulse Generator pulse-
width (ms)
0 to 14.1222
33.3333
Display the High interval width of the
pulse in milliseconds.
The duration between the Start Point and
End Point is calculated.
The setting range varies depending on
the [Clock Pre-scaler] value.
Pulse Generator Repeat
Count
0 to 255
0
Set the repeat count for the counter.
When this is set to [0], a free counter is
enabled with no repeat limit.
Pulse Generator Clear
Activation
Off,
High Level,
Low Level,
Rising Edge,
Falling Edge
Off
Set the clear signal condition for the
count clear input of the pulse generator.
Pulse Generator Clear
Source
Low,
High,
Frame Trigger Wait,
Frame Active,
Exposure Active,
FVAL,
LVAL,
User Output 0,
User Output 1,
Line4 - TTL In,
Line7 - CC1,
Nand0 Out,
Nand1 Out
Low
Select the count clear input signal source.
[Line4 TTL In] can be used on the
Standard Model.
Pulse Generator Clear
Inverter
True, False
False
Select whether to invert the polarity of the
count clear input signal.
Pulse Generator Clear
Sync Mode
Async Mode,
Sync Mode
Async Mode
Select the sync mode for the count clear
input signal.
i) Transport Layer Control
Display information on transport layer
control.
Device Tap Geometry
Geometry_1X2_1Y,
Geometry_1X3_1Y,
Geometry_1X4_1Y
Geometry_1X4_
1Y
Set the transmission method for each time
images are transmitted from the device
(TAP structure).
Camera Link Clock Frequency
37.1MHz,
74.3MHz,
84.9MHz
74.3MHz
Set the Camera Link clock.
j) User Set Control
Configure user settings.
User Set Selector
0: Default,
User Set1 to User Set3
Default (factory
default values)
Select the user settings.