— 51 —
GO-5101M-PMCL / GO-5101C-PMCL
Item
Setting range
Default value
Description
User Set Load
—
—
Load user settings.
User Set Save
—
—
Save the current setting values as user
settings.
k) JAI Custom Control ALC
Configure JAI ALC settings. These
settings are also used for AGC (auto gain
control).
ALC Reference
10 to 95
50
Set the target level for ALC. (unit: %)
ALC Area Selector
Low Right,
Low Mid-Right,
Low Mid-Left,
Low Left,
Mid-Low Right,
Mid-Low Mid-Right,
Mid-Low Mid-Left,
Mid-Low Left,
Mid-High Right,
Mid-High Mid-Right,
Mid-High Mid-Left,
Mid-High Left,
High Right,
High Mid-Right,
High Mid-Left,
High Left
Low Right
Select the area for which to configure
[ALC Area Enable].
ALC Area Enable
True, False
False
Enable/disable the photometry area
selected in [ALC Area Selector].
ALC Area Enable All
Off, On
Off
On: Operate ALC with all areas
designated as photometry areas,
regardless of the individual enabled/
disabled photometry area states
configured in [ALC Area Selector].
Off: Operate ALC according to the
individual enabled/disabled
photometry area states configured in
[ALC Area Selector].
ASC Min.
100 to 7999999
100
Set the minimum value for the Exposure
Auto (ASC) control range.
ASC Max.
101 to 8000000
8216
Set the maximum value for the Exposure
Auto (ASC) control range.
AGC Min.
100 to 1599
100
Set the minimum value for the Gain Auto
(ASC) control range.
AGC Max.
101 to 1600
1600
Set the maximum value for the Gain Auto
(ASC) control range.
AGC/ASC Control Speed
1 (slow) to 8 (fast)
4
Set the reaction speed for AGC/ASC.
(8 is the fastest.)
ALC Status
Display the counter ALC.
l) JAI Custom Control AWB
Configure settings for JAI AWB.
AWB Area Selector
Low Right to High Left
Low Right
Select from the 16 metering areas for
AWB individually.
AWB Area Enable
True, False
False
Enable / disable the selected AWB
metering area.
AWB Area Enable All
True, False
True
Enable / disable all AWB metering area.
AWB Control Speed
1 to 8
4
Select the AWB reaction speed. (for
continuous)
AWB Status
—
Idle
Display the counter AWB.
m) JAI Custom Control Blemish
Configure settings for JAI white blemish
correction.
Blemish Enable
True, False
True
Enable/disable blemish correction.
Blemish Detect
—
—
Execute blemish detection
Blemish Detect Threshold
0 to 100
10
Set the blemish detection threshold.
Blemish Detect Position Index
0 to 511
0
Select the index for the target blemish
coordinates (Blemish Data Position X/Y).