Setting List
- 74 -
Digital IO Control
Related Topic:
GPIO (Digital Input/Output Settings)
Configure settings for digital input/output.
Digital IO Control
Item
Setting Range
Default
Description
Line Selector
Line1 - TTL Out
Line4 - TTL In
Line7 - CC1
NAND Gate 0 In 1
NAND Gate 0 In 2
NAND Gate 1 In 1
NAND Gate 1 In 2
Line1 - TTL
Out
Select the input/output to configure.
Line Mode
Input, Output
Output
Display the input/output status (whether it is input or output).
Line Inverter
True, False
0
Enable/disable polarity inversion for the selected input
signal or output signal.
Line Status
True, False
0
Display the status of the input signal or output signal (True:
High, False: Low).
LineSource
Low
High
Frame Trigger Wait
Frame Active
Exposure Active
FVAL
Pulse Generator 0
User Output 0
User Output 1
Line4 - TTL In
Line7 - CC1
Nand 0 Out
Nand 1 Out
Low
Select the line source signal for the item selected in Line
Selector.
Line Format
-
TTL
Display the current I/F type.
User Output Selector
User Output 0, User Output 1
0: User
Output 0
Set the user output signal.
User Output Value
True, False
0
Set the value for the User Output selected in User Output
Selector.