SequencerFrameCount
: This configures the number of frame acquisitions for the selected
SequencerIndex.
SequencerReset
: During TriggerSequencer mode operation, this switches the index number to be
executed to that specified in SequencerSetStart.
SequencerRepetition
: This parameter applies to TriggerSequencer patterns which include an index
whose SequencerROINextIndex is set to 0 (OFF).
When the index whose SequencerROINextIndex is set to 0 (OFF) is finished executing, the value of
Sequencer Repetition (range = 1
~
255) is decremented internally. If the result of the decrement is not
zero, the TriggerSequencer pattern starts over from the index specified in SequencerSetStart. If the
result of the decrement is zero, the status changes to Acquisition Stop and external triggers are not
accepted.
Sample TriggerSequencer Mode Operation
User-Defined Indexes (Up to 32)
1. Specify "1" in SequencerSetStart, and start TriggerSequencer mode with index 1.
2. Based on the SequencerFrameCount setting (= 2), capture a 2-frame image with the first and
second triggers.
3. For the next index, configure index 3 specified in SequencerSetNext, and capture an image with
the number of frames (the number of triggers) specified in SequencerFrameCount (=1).
4. Proceed to sequence from index 4 to index 2 to index 1.
Note:
In addition to repeating multiple conditions as in the above example, you can specify "0"
(which indicates the end of TriggerSequencer mode) in SequencerSetNext of index 2, and specify