User Manual (Ver. 1.0) - Setting List
GOX-5105MC-PGE | GOX-8105MC-PGE | GOX-12405MC-PGE | GOX-16205MC-PGE | GOX-20405MC-PGE | GOX-24505MC-PGE
- 131 -
Digital IO Control
Item
Setting
Range
Default
Value
Description
LineSource
-
-
Select the line source signal for the item selected in LineSelector.
0: Off (Only when LineSelector is set to TimestampReset)
1: AcquisitionActive
2: FrameActive
4: ExposureActive
5: FVAL
7-10: PulseGenerator0-3
11-14: UserOutput0-3
15-18: Action0-3 (only when LineSelector=TimestampReset)
24: Line5 Opt In1
36: Nand0 Out
37: Nand1 Out
40: - (Not selectable for Output and NAND In)
41: Low
42: High
43: AcquisitionTriggerWait
44: FrameTriggerWait
※
LineSelector=24 is fixed to "-".
Default
LineSelector=TimestampReset: Off(0)
LineSelector=Other than TimestampReset: Line5 Opt In1 (24)
LineFormat
-
-
Display the signal format.
2: TTL
5: OptoCoupled
7: Internal Signal
Default
LineSelector=21,24: OptoCoupled
LineSelector=53,54,55,56,63: Internal Signal
LineStatusAll
-
-
Display the input/output signal status. The state is shown with 16 bits. Bit
assignments are as follows.
bit0: Unused (Fixed to 0)
bit1: Line2
bit2 - 3: Unused (Fixed to 0)
bit4: Line5
bit5 - 11: Unused (Fixed to 0)
bit12: Nand0 In1
bit13: Nand0 In2
bit14: Nand1 In1
bit15: Nand1 In2
OptInFilter (ns)
0
~
40000000
0
Remove noise from the OptIn input signal of Digital I/O. Step: 100
Setting Range:
0
~
40ms