Auto Level Control
Item
Setting
Range
Default
Value
Description
ALCAreaEnableAll
0: False
1: True
1: True
True: Operate ALC with all areas designated as photometry areas, regardless of the
individual enabled/disabled photometry area states configured in ALCAreaSelector.
False: Operate ALC according to the individual enabled/disabled photometry area
states configured in ALCAreaSelector.
ALCControlRatio
1
~
100
90
Set the response speed (%). (100 is the fastest.)
AutoControlStatus
-
0: Idle
Allows confirmation of the AGC, ASC, and AWB convergence status.
0: Idle
1: Processing - Exposure Time
2: Processing - Gain
3: Converging - Exposure Time
4: Converging - Gain
5: Error1 - could not processing
6: Error2 - timeout
ExposureAuto
ControlMin
-
100
Set the minimum value for the ExposureTime control range. (us)
Min
: 100
Max
: ExposureTimeMax-1
ExposureAuto
ControlMax
-
Exposure
TimeMax
Set the maximum value for the ExposureTime control range. (us)
Min
: ExposureAutoCon1
Max
: ExposureTimeMax
GainAutoControlMin
-
1
Set the minimum value for the GainAuto control range. (Step
≒
0.1dB)
Min
: 1
Max
: (GainAutoControlMax - 1)
GainAutoControlMax
-
126
Set the maximum value for the GainAuto control range. (Step
≒
0.1dB)
Min
: GainAutoCon1
Max
: 126