User Manual (Ver. 1.0) - Main Functions
GOX-5105MC-PGE | GOX-8105MC-PGE | GOX-12405MC-PGE | GOX-16205MC-PGE | GOX-20405MC-PGE | GOX-24505MC-PGE
- 70 -
GOX-5105M-PGE, GOX-5105C-PGE
Exposure Mode = Timed (Frame Start Trigger On, RCT Mode)
Pixel Format
Frame Period [A] (usec)
Period From Trigger Start
Edge to Exposure Start [B]
(usec)
Data Invalid Period [C]
(usec)
Full (Max Frame Rate), Exposure Time Minimum
Mono8
102339
1862.0
57755
Mono10
Mono12
102318
1862.2
16052
Mono10Packed
Mono12Packed
102317
1862.2
36860
BayerRG8
102339
1862.0
57755
BayerRG10
BayerRG12
102318
1862.2
16052
BayerRG10Packed
BayerRG12Packed
102317
1862.2
36860
Binning Horizontal (Max Frame Rate), Exposure Time Minimum
Mono8
102336
1862.0
78586
Mono10
Mono12
102318
1862.0
57706
Mono10Packed
Mono12Packed
102318
1862.0
68124
Binning Vertical (Max Frame Rate), Exposure Time Minimum
Mono8
102336
1862.0
78587
Mono10
Mono12
102318
1862.0
57693
Mono10Packed
Mono12Packed
102318
1862.0
68116
Binning Horizontal & Binning Vertical (Max Frame Rate), Exposure Time Minimum
Mono8
102318
1862.2
83052
Mono10
Mono12
102318
1862.0
78541
Mono10Packed
Mono12Packed
102318
1862.0
83051