User Manual (Ver. 1.0) - Main Functions
GOX-5105MC-PGE | GOX-8105MC-PGE | GOX-12405MC-PGE | GOX-16205MC-PGE | GOX-20405MC-PGE | GOX-24505MC-PGE
- 42 -
Trigger Control
Related Setting Items:
The camera allows the following controls to be performed via external trigger signals.
TriggerSelector
Description
AcquisitionStart
Start image acquisition in response to the external trigger signal input.
AcquisitionEnd
Stop image acquisition in response to the external trigger signal input.
FrameStart
Start capturing a one-frame image in response to the external trigger signal input.
Select this to perform exposure control using external triggers.
Note:
The FrameStart Trigger can only be used when the
setting is set to
Timed
.
AcquisitionTransferStart
Start output of acquired image data in response to external trigger signal input
(delayed readout).
Note:
See the
topic for the number of frames that can be
acquired on each model.
Notes:
l
The settings for exposure control and triggers are related to each other. Be sure to configure
the settings described in
l
You can delay when exposure actually starts after a trigger is received for a specific amount
of time by configuring
TriggerDelay
.