SingleFrameRecording: Acquire a single image and store onto the onboard memory. Images can
be read from the camera using SingleFrameReadout.
•
SingleFrameReadout: A single image will be read from the onboard memory. If no frames are
available, a timeout may occur in some software. To retrieve the next image simply execute
AcquisitionStart once.
AcquisitionStart
: tells the camera to start acquiring images in the mode as specified by
AcquisitionMode.
AcquisitionStop
: tells the camera to stop acquiring images.
AcquisitionFrameCount
: specifies the number of frames to be acquired in the MultiFrame Acquisition
mode. Valid range is from 1 to 255.
AcquisitionRecordingWrapAround
: for use with ContinuousRecording mode. Possible options:
•
True: when the recording buffer is full the oldest recorded image will be overwritten by the
newest image.
•
False: continuous recording will stop when buffer is full.
BlockBufferCount
: shows the number of images recorded. The number of available Block Buffers
depends on image size, GevSCPSPacketSize, and GrbCh0AcqCfgMemoryWaterLevel. It is
recommended to use at least 1440 for GevSCPSPacketSize. See “PLC Grabber Features” in section
5.8.7 for a description of GrbCh0AcqCfgMemoryWaterLevel.
BlockBufferCurrentIndex
: for use with ContinuousReadout and SingleFrameReadout modes. Sets the
index of the image that would be delivered next when AcquisitionStart or Start Acquisition is
executed. Index 0 refers to the oldest image. Subsequent AcquisitionStart commands automatically
increment this value. It is a write only register so you will not see the value change.
ExposureMode
: specifies mode of operation for the exposure control (or shutter). All Async modes,
and PulseWidthControl require a trigger signal. The possible options are:
•
Off: No shutter.
•
ContinuousProgrammable: Puts the camera into ContinuousProgrammable mode and enables
the ContinuousProgrammable value feature below.
•
AsyncNoShutter: this mode is meant to be used in a dark environment in conjunction with
strobe light. This setting and all settings below require a trigger signal.
•
PulseWidthControl
•
AsyncProgrammable: Puts the camera into AsyncProgrammable mode and enables the
AsyncProgrammable value feature below.
ContinuousProgrammable
: user defined shutter time in unit of scan lines. Available only when
ExposureMode is in ContinuousProgrammable.
AsyncProgrammable
: user defined shutter time in unit of scan lines. Available only when
ExposureMode is in AsyncProgrammable. Requires trigger signal.
TriggerPolarity
: this feature selects which signal state, high or low, of the trigger signal will initiate
an image capture for triggered ExposureModes.
5.2
AnalogControls
These controls allow you to make adjustment to image intensities (Gain), Black Level, and auto black
level.