④
CXP frame grabber board
Refer to the operating instructions of the frame grabber board, and configure
settings on the computer as necessary.
⑤
DC IN / trigger IN connection cable
⑥
AC adapter (power supply)
Connect the AC adapter and the round connector of the connection cable to the DC
IN / TRIG IN connector on the camera.
Step 2: Verifying Camera Operation
When power is supplied to the camera while the necessary equipment is connected, the
POWER/TRIG LED at the rear of the camera lights amber, and initialization of the camera
starts. When initialization is complete, the POWER/TRIG LED lights green.
Verify whether power is being supplied to the camera by checking the rear LED.
When properly turned on
Lit green
•
For details on how to read the LEDs, see “LED status and camera status” in the
“Parts Identification” section.
•
Initialization of the camera is not complete until connection with the host is
established. If the power / trigger LED does not switch to green within minutes of
supplying power, check the CXP cable and other connections. After initialization is
completed once, the power / trigger LED will remain green, even if the host is
disconnected.
Step 3:
Verifying the Connection between the Camera and PC
Use the appropriate tool for the CoaXPress frame grabber board to be used to set up the
camera and display captured images. Refer to the operation manual of the tool to be
used for the operation method.