Acquisition
Control
■ When [ExposureMode] is [TriggerWidth]
(Next trigger disabled)
Next trigger
Input enabled
B
ExposureTime
Trigger
Sensor
Exposure
Exposure
Active
Readout
A (Frame Period)
D
C
• FrameStartTrigger On
SP-45000M-CXP4A/SP-45000C-CXP4A
PixelFormat
Frame Period [A] (usec)
Period From Trigger start edge to
Exposure start [B] (usec)
Period From Trigger end to
Exposure end [C] (usec)
Period From Exposure end to next
Trigger Start [D]
(usec)
Mono8
19685
37.4
37.4
19596
Mono10
21009
37.4
37.4
22789
Mono12
21009
37.4
37.4
20920
BayerRG8
19685
37.4
37.4
19596
BayerRG10
21009
37.4
37.4
20921
BayerRG12
21009
37.4
37.4
20920
Mono8
19570
37.4
37.4
19481
Mono10
20921
37.4
37.4
20833
Mono12
21009
37.4
37.4
20917
Mono8
19842
37.4
37.4
19715
Mono10
22936
37.4
37.4
20921
Mono12
28012
37.4
37.4
20920
Mono8
19608
37.4
37.4
19520
Mono10
22989
37.4
37.4
20921
Mono12
28012
37.4
37.4
21373
Horizontal Binning On & Vertical Binning On
Vertical Binning On
Horizontal Binning On
Binning Off
CXP12-4