In the Multi ROI mode, you can specify up to 64 scanning areas for a single-frame image.
The areas cannot overlap.
The Multi ROI mode can be used only when both the Sequencer mode and the Shading
mode are off.
Set [MultiROIControl]->[MultiRoiMode] On. Select from the eight indexes in
[MultiRoiIndex] then set [MultiRoiWidth], [MultiRoiHeight], [MultiRoiOffsetX] and
[MultiRoiOffsetY].
And set the maximum index number to be enabled to [MultiRoiVerticalEnableNumber]
and [MultiRoiHorizontalEnableNumber].
■
Example
JAI
ROI Function (Multi ROI)
OffsetY[0]
OffsetY[1]
OffsetX[0]
OffsetX[1]
Width[0]
Width[1]
Height[0]
Height[1]
Height[0] + Height[1]
Width[0] + Width[1]
Multi ROI
Control
To use four areas as shown below, refer to the following.
1. Set [MultiROIControl]->[MultiRoiMode] On.
2. Select “0” in [MultiRoiIndex].
Set [MultiRoiWidth], [MultiRoiHeight], [MultiRoiOffsetX] and [MultiRoiOffsetY].
3. Select “1” in [MultiRoiIndex].
Set [MultiRoiWidth], [MultiRoiHeight], [MultiRoiOffsetX] and [MultiRoiOffsetY].
4. Set 2 to [MultiRoiVerticalEnableNumber].
5. Set 2 to [MultiRoiHorizontalEnableNumber].
Using areas
(four green areas)
Output image
SP-45000M-CXP4A/SP-45000C-CXP4A
- 45 -