PulseGeneratorClock
OutputSignal
ClearSourceSignal
StartPoint
EndPoint
Width
Length
Settings
PulseGeneratorStartPoint = 2
PulseGeneratorEndPoint = 6
PulseGeneratorLength = 10
PulseGeneratorPulseWidth = 4
PulseGeneratorClearSyncMode = AsyncMode
Pulse Generator
By using this function, any signal can be generated inside the camera.
The following is an example of signal generation.
The table below shows the PulseGeneratorClearSource signals that can be set.
O
ff
Acq
ui
sit
io
nA
ct
ive
Fra
m
eA
ctiv
e
Ex
po
sur
eA
ct
ive
FVA
L
LVA
L
Pu
lse
Ge
ne
rat
or0
Pu
lse
Ge
ne
rat
or1
Pu
lse
Ge
ne
rat
or2
Pu
lse
Ge
ne
rat
or3
Us
erO
ut
put
0
Us
erO
ut
put
1
Us
erO
ut
put
2
Us
erO
ut
put
3
Lin
e4
Lin
e5
Lin
e7
Lin
e1
0
Na
nd
0O
ut
Na
nd
1O
ut
Lo
w
Hi
gh
Ac
qu
is
itio
nT
rig
ge
rW
ait
Fra
m
eT
rig
ge
rW
ait
PulseGenerator0
✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
✓ ✓
PulseGenerator1
✓ ✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
✓ ✓
PulseGenerator2
✓ ✓ ✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
✓ ✓
PulseGenerator3
✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
✓ ✓
Pulse
Generator
SP-45000M-CXP4A/SP-45000C-CXP4A
Technical notes
The Pulse Generator function –
what it is and how to use it
- 53 -