SP-5000M-GE2 / SP-5000C-GE2
- 50 -
6.3.3 ROI (Region Of Interest) setting
In the SP-5000-GE2, a subset of the image can be output by setting Width, Height, Offset-X, and Offset-Y.
If the height is decreased, the number of lines read out is decreased and as the result, the frame rate is
increased. However, in the horizontal direction, the horizontal frequency is not changed if the width is
decreased. In the SP-5000-GE2, the minimum width is “8” and minimum height is “8”.
OffsetX
Width
OffsetY
Height
Width
2560 Width Max
2
0
4
8
H
e
ig
h
t
M
ax
Readout area
Fig.21
Setting example ( No binning)
Fig.22
Setting example (Binning)
6.4 Digital output Bit allocation
Table17. Digital output
CCD out
Digital Out
8-bit
10-bit
12-bit
Black
0%
8LSB
32LSB
128LSB
Monochrome
100%
222LSB
890LSB
3560LSB
Color
Monochrome
115%
255LSB
1023LSB
4095LSB
Color
Digital
Out
[LSB]
32
700
25
Analog Out [mV]
890
1023
Black
Level
0
White Clip Level
800
100%
Level
Fig.23 Bit allocation (10-bit)
Setting example (1)
Binning Horizontal = 1
Binning Vertical = 1
Setting example (2)
Binning Horizontal = 2
Binning Vertical = 2
OffsetX
OffsetY
Height
Width
1280 Width Max
1
0
2
4
H
e
ig
h
t
M
ax
Readout area