SP-5000M-GE2 / SP-5000C-GE2
- 41 -
5.5.9 Pulse Generator Clear Source
The following clear source can be selected as the pulse generator clear signal.
Table14. Pulse generator clear source
Pulse Generator
Clear Source
item
Description
Low
Connect Low level signal to Clear Source for the selected pulse generator.
Default setting
High
Connect High level signal to Clear Source for the selected pulse
generator.
Frame Trigger Wait
Connect Frame Trigger Wait signal to Clear Source for the selected pulse
generator.
Frame Active
Connect Frame Active signal to Clear Source for the selected pulse
generator.
Exposure Active
Connect Exposure Active signal to Clear Source for the selected pulse
generator.
Acquisition Trigger
wait
Connect Acquisition Trigger Wait signal to Clear Source for the selected
pulse generator.
Acquisition Active
Connect Acquisition Active signal to Clear Source for the selected pulse
generator.
FVAL
Connect FVAL signal to Clear Source for the selected pulse generator.
LVAL
Connect LVAL signal to Clear Source for the selected pulse generator.
PulseGenerator0
Out
Connect Pulse Generator 0 output to Clear Source for the selected pulse
generator.
PulseGenerator1
Out
Connect Pulse Generator 1 output to Clear Source for the selected pulse
generator.
PulseGenerator2
Out
Connect Pulse Generator 2 output to Clear Source for the selected pulse
generator.
PulseGenerator3
Out
Connect Pulse Generator 3 output to Clear Source for the selected pulse
generator.
Action 1
Connect Action 1 input to Clear Source for the selected pulse generator.
Action 2
Connect Action 2 input to Clear Source for the selected pulse generator.
User output0 Out
Connect User output 0 to Clear Source for the selected pulse generator.
User output1 Out
Connect User output 1 to Clear Source for the selected pulse generator.
User output2 Out
Connect User output 2 to Clear Source for the selected pulse generator.
User output3 Out
Connect User output 3 to Clear Source for the selected pulse generator.
Line 5 Opt 1 In
Connect Opt 1 In signal to Clear Source for the selected pulse generator.
Line 6 OPT2 in
Connect Opt 1 In signal to Clear Source for the selected pulse generator.
Nand 0 Out
Connect NAND 0 output signal to Clear Source for the selected pulse
generator.
Nand 1 Out
Connect NAND 1 output signal to Clear Source for the selected pulse
generator.
Line 10 TTL 2 In
Connect TTL 2 In signal to LINE 10.
Line 11 LVDS 1 In
Connect LVDS 1 In signal to Line 11
Note:
The pulse generator output cannot be used as the clear input to the same pulse generator. Refer
to
“
5.3.7.2. Table 10
”
.