SP-5000M-GE2 / SP-5000C-GE2
- 78 -
7.10.1 Multi ROI setting parameters
(1) Multi ROI Index Max
:
Setting value = 0
~
4
Maximum 5 ROI settings are possible in a frame. Set Index 0 through 4 in Multi ROI Index
table as an application requires.
(2) Multi ROI Width
Multi ROI Width can be set individually for Multi ROI Index 0 to 4. The setting range and
Step number are the same as the normal ROI setting in which
“
Video Send Mode
”
is set to
”
Normal
”
. The restriction for setting Step and other factors are
the same as the normal ROI setting.
(3) Multi ROI Index Selector
:
Index 0 to 4 can be selected. [Height], [Offset X], and [Offset Y] of the selected Multi ROI
Index are displayed and can be set.
(4) Multi ROI Offset X
:
Offset X can be set for each ROI area of Multi ROI Index 0 to 4.
The restriction for setting Step and other factors are the same as the normal ROI setting.
The sum of Offset X and ROI Width must not be greater than Width Max.
(5) Multi ROI Height
:
Height can be set for each ROI area of Multi ROI Index 0 to 4.
The restriction for setting Step and other factors are the same as the normal ROI setting.
(6) Multi ROI Offset Y
:
Offset Y can be set for each ROI area of Multi ROI Index 0 to 4.
The restriction for setting Step and other factors is the same as the normal ROI setting.
The sum of Offset Y and ROI Height must not be greater than Height Max.