SP-5000M-GE2 / SP-5000C-GE2
- 81 -
x16
x1
16
1
Gain
Amplitude
Gain
Setting
Value
Gain Control Range for
Monochrome
24dB
0dB
The master gain control uses Digital Gain Control. All digital gain can be set by x0.01/step. If the
digital gain is set too high, a break in the Histogram may occur.
The above drawing shows the relation among gain setting value (command), gain amplitude,
and dB indication. For example, the gain amplitude “x 5.643” equals 15dB.
Fig.44 Gain control
8.2.1 Gain Selector
The following parameters can be set.
SP-5000M-GE2: DigitalAll
SP-5000C-GE2: DigitalAll/Digital Red All/Digital Blue All
8.2.2 Gain
This is the reference value upon which gain adjustments are based. The operational adjustment is
done in Gain Raw.
SP-5000M-GE2: DigitalAll
:
1
~
16 (0dB to +24dB)
SP-5000C-GE2: DigitalAll
:
1
~
16 (0dB to +24dB)
Digital Red All
:
0.4466
~
5.643
Digital Blue All
:
0.4466
~
5.643
8.2.4 Gain Auto
This function automatically controls the gain level.
This is controlled by the command JAI ALC Reference.
There are three modes.
OFF:
Adjust manually.
Once:
Operate only one time when this command is set
Continuous:
Operate the auto gain continuously
The following detailed settings are also available.
ALC Speed:
The rate of adjustment of GainAuto can be set (Common with
ExposureAuto).
X90.288
X16
X7.15
X5.643
X1
X0.45
16
1
Gain
Gain
Setting
Value
5.643
0
0.4466
Gain
Setting
Value
Master
R&B
Master
Red
Blue
Gain Control Range for Bayer Color
39dB
-7dB
0dB
24dB
15dB
0dB
-7dB
15dB
0dB
-7dB
15dB
0
0.4466
17dB
5.643