SP-5000M-GE2 / SP-5000C-GE2
- 67 -
Table23. Trigger source
7.3.4 Trigger activation
This command can select how to activate the trigger.
Rising Edge:
At the rising edge of the pulse, the trigger is activated.
Falling Edge: At the falling edge of the pulse, the trigger is activated.
Note: When Trigger Width mode is used, the trigger is initiated at the rising edge or falling
edge and the exposure time is the duration at the falling edge or rising edge of the
trigger input pulse.
7.3.5 Trigger Overlap
This function defines whether or not a trigger pulse can be accepted while data is being read out.
OFF
:
The trigger pulse is not accepted during the sensor readout.
Read Out
:
The trigger pulse can be accepted during the sensor readout.
Trigger Source
item
Description
Low
Connect LOW level signal to the selected trigger operation
Default setting
High
Connect HIGH level signal to the selected trigger operation
Soft Trigger
Connect Soft Trigger signal to the selected trigger operation
Trigger can be input manually by the execution of the software trigger
Trigger software is available on each trigger source.
PulseGenerator0
Out
Connect Pulse generator 0 signal to the selected trigger operation
PulseGenerator1
Out
Connect Pulse generator 1 signal to the selected trigger operation
PulseGenerator2
Out
Connect Pulse generator 2 signal to the selected trigger operation
PulseGenerator3
Out
Connect Pulse generator 3 signal to the selected trigger operation
Line 5 - OPT IN 1
Connect TTL 1 IN signal to the selected trigger operation
Line 6 - OPT IN 2
Connect OPTO IN 1 signal to the selected trigger operation
NAND 0 Out
Connect NAND 0 OUT signal to the selected trigger operation
NAND 1 Out
Connect NAND 1 OUT signal to the selected trigger operation
User Output 0
Connect User Output 0 signal to the selected trigger operation.
0 or 1 status can be sent by User 0 command from PC (Host side).
User Output 1
Connect User Output 1 signal to the selected trigger operation.
0 or 1 status can be sent by User 0 command from PC (Host side).
User Output 2
Connect User Output 2 signal to the selected trigger operation.
0 or 1 status can be sent by User 0 command from PC (Host side).
User Output 3
Connect User Output 3 signal to the selected trigger operation.
0 or 1 status can be sent by User 0 command from PC (Host side).
Action1
Connect Action 1 signal to the selected trigger operation.
Action2
Connect Action 2 signal to the selected trigger operation.
Line 10 - TLL IN 2 Connect TTL 2 IN signal to Line 10
Line 11 - LVDS IN Connect LVDS 1 IN signal to Line 11