SP-5000M-GE2 / SP-5000C-GE2
- 37 -
5.4 Optical Interface
SP-5000-GE2 is equipped with opto-isolated inputs and outputs, providing galvanic separation
between the camera’s inputs/outputs and peripheral equipment.
In addition to galvanic separation, the opto-isolated inputs and outputs can cope with a wide range
of voltages; the voltage range for inputs is +3.3V to +24V DC whereas outputs will 5V to
+24V DC.
The following drawing is the concept of photo coupler
Fig.7 Photo coupler
5.4.1 Recommended External Input circuit diagram for customer
Fig.8 Example of external input circuit
5.4.2 Recommended External Output circuit diagram for customer
+3.3V
Fig.9 Example of external output circuit