SW-4010Q-MCL-M52 User Manual (Tentative)
Main Functions
- 48 -
Pixel Sensitivity Correction
Related Topic:
Correct variations between the sensor’s pixels.
Calibration must be performed within the camera and correction data must be created
beforehand. DSNU (PixelBlackCorrect) / PRNU (PixelGainCorrect) can be reduced using that
correction data.
We recommend performing calibration and creating correction data whenever the line rate setting
or Analog base gain setting or vertical binning setting are changed significantly.
Refer to the following topics on how to perform the calibration.
l
PRNU Correction (Pixel Gain Correct)
l
DSNU Correction (Pixel Black Correct)
Notes:
l
Correction data is saved for DSNU (PixelBlackCorrect) / PRNU (PixelGainCorrect)
according to the conditions adjusted at the factory.
l
We recommend performing DSNU and PRNU calibration again whenever the line rate
setting is changed significantly.
l
A single correction data entry can be saved on the camera for each user. When
calibration is performed, the correction data is saved to the non-volatile ROM at the
same time.