SW-4010Q-MCL-M52 User Manual (Tentative)
Setting List
- 78 -
Analog Control Item
Setting Range
Default
Value
Description
AWBExposureOnce
Status
-
5:Idle
When
BalanceWhiteAuto
is set to
ExposureOnce
, display the status.
1:Succeeded
2:Error1- G image was too bright
3:Error2 - G image was too dark
4:Error3 - Timeout
5:Idle
Gamma
Related Topic:
0.45 ~ 1
0.45
Set the Gamma value.
Setting Range: 0.45, 0.50, 0.55, 0.60, 0.65, 0.75, 0.80, 0.90, 1.00
LUTMode
0: Off
1: Gamma
2: LUT
0:Off
Set the LUT mode.
LUTControl
Configure LUT settings.
Related Topic:
LUT Control Item
Setting Range
Default Value
Description
LUTSelector
0: Red
1: Green
2: Blue
0: Red
Select the LUT channel to control.
Note:
Color models only.
LUTIndex
0 ~ 256
0
Set the LUT index table number.
LUTValue
0 ~ 4095
Gamma
≒
1.0
Set the LUT value.