SW-4010Q-MCL-M52 User Manual (Tentative)
Setting List
- 87 -
PulseGenerator
Configure pulse generator settings.
Pulse Generator Item
Setting Range
Default Value
Description
ClockPreScaler
1 ~ 4096
1
Set the division value for the prescaler (12 bit) using
PixelClock as the base clock.
PulseGeneratorClock (MHz)
-
100
Set the clock used for the pulse generator. This value
is calculated using the ClockPreScaler value as a
base.
PulseGeneratorClock = 100 / ClockPreScaler
PulseGeneratorSelector
0:PulseGenerator0
1:PulseGenerator1
2:PulseGenerator2
3:PulseGenerator3
0:PulseGenerator0 Select the pulse generator.
PulseGeneratorLength
1 ~ 1048575
30000
Set the maximum count-up value as a clock count.
PulseGeneratorLengthMs
(ms)
-
0.3
Set the maximum count-up value in milliseconds.
This value is calculated using the
PulseGeneratorLength value as a base. The setting
range varies depending on the ClockPreScaler value.
PulseGeneratorLengthMs = 1/PulseGeneratorClock *
PulseGeneratorLength
PulseGeneratorFrequency
(Hz)
-
3333.333333
Set the maximum count-up value as a frequency (Hz).
This value is calculated using the
PulseGeneratorLength value as a base.
PulseGeneratorFrequency = 1sec /
PulseGeneratorLengthMs
PulseGeneratorStartPoint
0 ~ 1048575
0
Set the start point of the High interval as a clock
count. When the counter reaches this value, the
output will be 1.
PulseGeneratorStartPointMs
(ms)
-
0
Set the start point of the High interval in milliseconds.
When the counter reaches this value, the output will
be 1. The setting range varies depending on the
ClockPreScaler value.
PulseGeneratorStartPointMs =
1/PulseGeneratorClock * PulseGeneratorStartPoint
PulseGeneratorEndPoint
1 ~ 1048575
15000
Set the start point of the Low interval as a clock count.
When the counter reaches this value, the output will
be 0.