SW-4010Q-MCL-M52 User Manual (Tentative)
Setting List
- 93 -
SWIR Acquisition Item
Setting Range
Default
Value
Description
SWIRAcquisitionLineRate
(Hz)
Related Topic:
500.012 ~
39215
39215
Specify the line rate (Hz).
SWIRExposureMode
Related Topic:
0: Off
1: Timed
1: Timed
Select the exposure mode.
SWIRExposureTime (us)
Related Topic:
20.4 ~ 1994.85 20.4
Specify the exposure time. (unit: us). Step: 0.1499
Note:
No exposure offset duration for the SWIR channel.
SWIRFreeRunSyncMode
0: Off (Asynch)
1: Timed
(Synch)
0: Off
(Asynch)
Synchronizes the operation of the RGB channels and the SWIR
channel when the trigger mode is off.
Off
Use the SWIR channel's free running operation.
On
Use the RGB channels' free funning operation; the line rate will
no longer be 149.9ns step ( = SWIR channel's normal operation
cycle).