SW-4010Q-MCL-M52 User Manual (Tentative)
Setting List
- 94 -
SWIRAnalogControl
Configure the analog control settings for the SWIR channel.
SWIR Analog Control Item
Setting
Range
Default Value
Description
SWIRSensOutCfa
Related Topic:
0: Zero
1: One
1: One
Set the sensor’s internal conversion gain.
SWIRSensOutCfb
0: Zero
1: One
1: One
Set the sensor’s internal conversion gain.
SWIRSensOutCfc
0: Zero
1: One
0: Zero
Set the sensor’s internal conversion gain.
SWIRAnalogBaseGain
0: -6dB
1: -3dB
2: 0dB
3: +3dB
2: 0dB
Set the analog base gain value.
SWIRGainSelector
-
0:Analog All
(fixed)
Display the Gain value to configure.
SWIRGain
1 ~ 3.572
1
Set the Gain value.
SWIRBlackLevelSelector
Related Topic:
-
0:Alll (fixed)
Select the black level to configure.
SWIRBlackLevel
-256 ~ 255
0
Set the black level value.
SWIRGamma
Related Topic:
-
0.45
Set the Gamma value.
Setting Range: 0.45, 0.50, 0.55, 0.60, 0.65, 0.75, 0.80,
0.90, 1.00
SWIRLUTMode
0: Off
1: Gamma
2: LUT
0:Off
Select the LUT mode.