44
Force Control Products
Model
JK-SE-VII-400NS
Range Fz (N)
400
Overload
200%
F.S.
Accuracy
0.5%
F.S.
Operating
Temperature
-40 to 100
℃
IP Rating
IP64
Power Voltage
9–24V
Communication
Interface
USB
2.1.6.5 Precautions for Use
a.
Do not use in any environment with temperature or humidity beyond the allowable range.
b.
The cable must be connected properly. Before powering on the sensor, please check whether the
cables are connected according to the colors indicated in this manual. A wiring mistake could cause a
short circuit and damage to the internal circuit of the sensor, so do not forget to check that the wiring is
correct.
c.
The sensor has built-in precision components such as embedded systems. Although we have carried
out relevant vibration and shock tests, it is still necessary to prevent it from dropping, which could
cause excessive vibration and subsequent malfunctions.
d.
Do not strike or knock the sensor when installing it, especially when installing it onto the mounting
flange. If the mounting clearance is tight due to the processed mounting flange, avoid striking or
knocking the sensor as it might result in damage.
e.
After the sensor is installed and powered on, it is recommended to warm up for one hour before
operating.
f.
When using the sensor, pay attention to the mass of the device mounted on it, which should be within
the payload range of the robot.
g.
If you have any doubts or if any faults occur during use, please do not attempt to operate the product.
Instead, contact us directly.
2.1.6.6 Reference Tightening Torques for Sensor Mounting Bolts
Reference tightening torques for sensor mounting bolts are as follows:
Table 2-16 Reference Tightening Torques for Sensor Mounting Bolts
Metric
Reference Tightening
Torque (Nm)
M2
0.4
M3
2.0
M4
4.0
M5
8.0
M6
13.0
M8
35.0
Summary of Contents for Zu Series
Page 1: ...JAKA ROBOTICS Force Control Products JAKA Se and JAKA Sp...
Page 3: ......
Page 4: ......
Page 17: ...Version 3 1 0 13 M3 2 0 M4 4 0 M5 8 0 M6 13 0 M8 35 0...
Page 41: ...Version 3 1 0 37 Figure 2 36 Installation and Dimensions of the Force Sensor Indicator light...
Page 61: ...Version 3 1 0 57 Figure 3 8 Force Display Interface of the App...
Page 75: ...Version 3 1 0 71 Figure 3 19 Force Display Interface of the App...
Page 79: ...Version 3 1 0 75 Figure 3 21 Collision Detection Function Settings of JAKA Zu Sp...