background image

About units

 

JR(H/V)(B)70 

www.jakkagroup.com

 

SAFETY STANDARDS AND “CE” MARKING

Our technicians are steadily engaged in research and development of more and 

more effi

cient products in compliance with the safety “standards” in force.

The standards and suggestions contained herein reflect the safety standards

in force and, therefore, are mainly based on the compliance of said general 

regulations.

Consequently, we would suggest all people exposed to risks to comply the acci-

dent prevention regulations in force in their respective countries.

JAKKA GROUP are exempted from any responsibility attributable to damage 

caused to persons and things resulting from the non-compliance with the safety 

standards and any product modifications. 

The CE marking and the relevant declaration of conformity prove the conformity 

to the applicable community regulations.

The products which are not provided with the CE marking must be certi

fi

ed by 

the purchaser who shall have to certify the conformity of the whole plant. 

Units 

are as prescribed by:

- Machinery directive 2006/42/EC 

- Low voltage directive EEC 2006/95 

- Electromagnetic compatibility directive 2004/108/EC 

And in accordance with the following harmonized standards: 

EN 60204-1:2005; EN 305:1997;EN 61000-6-3:2007

GENERAL

The safety protection devices may not be removed if this is not absolutely 

necessary.

In this case, suitable measures to point out the possible danger shall be imme-

diately taken. The restoration of said protection devices on the product shall take 

place as soon as the reasons for the temporary removal cease.

All (ordinary and extraordinary) maintenance interventions shall be carried out 

with disconnected machine and electrical and pneumatic supply. In order to avoid 

the risk of possible accidental starts, provide the electric panels, the central units 

and the switchboards with warning signals with the following reading “caution: 

control disconnected for maintenance works”.

Before connecting the electrical supply cable to the terminal board make sure 

that the line voltage is in compliance with the voltage stated on the machine 

plate.

If the supply cord is damaged it must be replaced by the manufacturer or authori-

zed service center or qualified personnel to avoid dangerous situations

Replace the product labels if, with the passing of time, they should become 

illegible.

The device should not be used by persons (including children) with reduced phy-

sical, sensory or mental capacities, or lack of experience or knowledge, unless 

they have been given, through the intermediary of a person responsible for their 

safety, supervision or instruction concerning use of the appliance.

Children should be supervised to ensure that they don't play with the device.

MAINTENANCE REGULATIONS

The personnel in charge with maintenance must keep to the accident prevention

regulations in force and to the following instructions:

- wear suitable accident prevention clothes

- when the noise exceeds the admissible levels, use protection headsets

- make sure that an interlock is provided so that the machine may not be started 

from non-authorized persons

INSTALLATION CONDITIONS

 

Installation allowed inside the buildings or outdoor, with temperature between 

-15° to +50° C

To avoid:

- areas near sources of heat source, steam or liquid flammable and/or explos -

ves gases, dusty areas, proximity to water sources such as baths, showers or 

swimming pools

- Do not touch the device with wet or damp hands or feet.

- Do not leave the device exposed to the atmospheric agents.

To consider:

- use the device only for the use for which it was built. The manufacturer can not 

be held responsible for any damage caused by improper or incorrect use.

- consider an area where the air flow and noise of the unit don’t disturb the

neighbors;

- minimum space required for the maintenance (as defined below)

- the wall must be suitable to the weight of the unit and don’t cause vibrations;

- a position that does not block passageways or entrances;

- measures to protect the fan vents with special protection to prevent contact with 

moving mechanical parts;

The protection degree is IP20. 

In case of outdoor installation:

- place the unit in a place sheltered from the weather;

- otherwise, use the weather protective roof (if required, use the weather protec-

tion cowl too). 

The protection degree changes in IP22

REMAINING RISKS

The risks of the products have been analyzed according to the Machine Directive. 

(all. I of Directive 2006/42/CE)

The present handbook contains information for all persons in charge and has 

the purpose to avoid possible damages to persons and/or things attributable to 

remaining risks.

IDENTIFICATION SIGNALS

Serial number plate: it states the product data and the manufacturer address.

PROHIBITION SIGNALS

Do not repair or adjust during motion 

DANGER/WARNING SIGNALS

They signal the presence of parts under voltage in the container on which the plate 

is provided.

GOODS RECEPTION

Each product is carefully checked before shipping. 

On goods reception, it is necessary to make sure that products have not suffered 

any damages during transport.

Products are loaded on pallets and fastened to them by means of straps and pro-

tection film or in self-supporting cardboard boxes which are fastened to pallets

HANDLING

Before displacing products, make sure that the means of transport employed has 

a suitable carrying capacity. 

According to the standard 89/391/CEE and following standards, manual lifting is 

admissible up to a max. weight of 20 Kg under shoulders level, but over floor level

STORAGE

Store the unit in a sheltered spot, without excessive moisture and not subject to 

sudden changes of temperature in order to avoid the formation of condensation 

inside the unit.

EXTENDED DOWNTIME

In the event of extended downtime with the unit connected to the system of venti-

lation, close the suction/ injection and periodically check the absence of humidity 

inside the machine. In case of condensation, wipe it dry it immediately.

START

Before starting it is opportune to carry out some checks: (follow the safety instruc-

tions in section DISASSEMBLY AND ASSEMBLY):

- Make sure there is no condensation inside the unit, and if necessary,wiipe it dry   

  before attempting to operate the unit;

- Check thefilters status

- Make sure that the product does not contain any foreign matters and that all 

  components are fastened in their seats;

- Try manually that the impeller does not rub on the walls;

- Make sure that the inspection door is closed.

CAUTION

:

If the fan mouths are not ducted, use a suitable protection net. Check the 

earth connection 

The electrical connection must be carried out by qualified personnel

DISASSEMBLY AND ASSEMBLY 

Before starting any operation, make sure that the product is excluded from any 

electrical connection and that the impeller is switched off. 

Disassembly and assembly are extraordinary maintenance operations and must 

be carried out by qualified personnel

DISPOSAL

Do not dismantle the system themselves: disassembly of the product and 

any other party, shall be performed by a qualified installer in accordance

with relevant 

local and national regulations in force

At the end of its operating life, the appliance should not be treated as household 

waste but, as a special waste, must be demolished in a safe recovery and disposal 

as required by the European Directive 2002/96/EC.

By ensuring this product is disposed properly, you will help prevent potential nega-

tive consequences for the environment and human health due to the presence of 

potentially hazardous substances.

For more detailed information about recycling of this product, please contact your 

city hall, your household waste disposal service or the shop where you purchased 

the product.

In the event of illegal disposal will apply the sanctions provided by law.

Summary of Contents for JRH(B)70/2000

Page 1: ...Manual JR H V B 70 JAKKA heat recovery unit JAK KA GROUP december 2019 www jakkagroup com J 8 Г ...

Page 2: ...da su sve objavljene informacije kompletne i tačne S toga Vas molimo u cilju bolje saradnje da pre konačne odluke proverite podatke sa našim prodavcima kako bismo izbegli greške Jakka Group zadržava pravo promene svih informacija u katalozima uputstvima i cenovnicima bez prethodne najave Content About units 2 Installation 3 Maintenance 9 Troubleshooting 10 ...

Page 3: ...red for the maintenance as defined below the wall must be suitable to the weight of the unit and don t cause vibrations a position that does not block passageways or entrances measures to protect the fan vents with special protection to prevent contact with moving mechanical parts The protection degree is IP20 In case of outdoor installation place the unit in a place sheltered from the weather oth...

Page 4: ...e ducting the connection to the supply mains through the terminal board boxes and the condensate discharge pipe fastening on the air exhaust side JRH B 70 900 JRH B 70 2000 JRH B 70 3000 JRH B 70 4500 JRH B 70 5600 MINIMUN SPACES REQUIRED FOR THE ORDINARY MAINTENANCE in mm Mod A B C D 360 535 630 855 855 400 400 500 500 500 400 600 700 900 900 820 1040 1270 1300 1300 A C B D D B B HORIZONTAL CONFI...

Page 5: ...pply mains See the description for the horizontal configuration The steam trap is one and presettled by the manufacturer Mod A B C 400 600 700 900 900 820 1040 1270 1300 1300 920 1140 1370 1300 1300 MINIMUN SPACES REQUIRED FOR THE ORDINARY MAINTENANCE in mm B C A 100 VERTICAL CONFIGURATION tfront view side inspection INSTALLATION OF THE UNIT front view side inspection BV Standard configuration fre...

Page 6: ...akkagroup com MOUNTING OPERATION OF CONDENSATE DRAINAGE INSTRUCTIONS TO ASSEMBLE THE CONDENSATE DRAIN 1 OPEN INSPECTION PANEL 3 CLOSE THE INSPECTION PANEL 2 POSITION THE WASHER INSERT THE CONDENSATE DRAIN INTO HOLE AND SCREW THE UNIT ...

Page 7: ...e circuit of ducts remote installation INSTALLATION OF THE WEATHER PROTECTION COWL The weather protection cowl SKMF R is recommended to protect ejection and suction mouths in case of installation outside the units birds rain etc BA AC RCF Electrical heater WRONG INSTALLATION Electrical heater RIGHT INSTALLATION ONLY POSSIBLE POSITION The unit is equipped with condensate drainage to evacuate the wa...

Page 8: ...G OPERATION OF EXTERNAL WEATHER PROTECTIVE CANOPY T JRH70 without by pass horizontal configuration JRH70 It is recommended to protect the unit installed outside by an external weather protective canopy T JRH70 with by pass horizontal configuration JRHB70 ...

Page 9: ...Installation JR H V B 70 www jakkagroup com 8 JRV70 with without by pass vertical configuration JRV70 JRVB70 ...

Page 10: ...ANCE AND CLEANING OF FILTERS With side access 1 2 3 4 6 5 With beneath access PRECAUTIONS IN HANDLING THE HEAT EXCHANGER Recommended periodical maintenance Filter replacement variable depending on environment air pollution dust fume Recommended periodical maintenance Exchanger cleaning 1 operation season approximately ...

Page 11: ...cuit check and restoration of original conditions b Check the impeller if necessary replace through an original spare part Air pulsation The fan capacity conditions are near zero flow instabilit clogging or wrong connection Increase the min speed on the electronic speed regulator insufficient voltage Modify the circuit and or replace the fan Clean and or restore the suction duct Excessive vibratio...

Page 12: ...11 2 600 901 faks 381 0 11 2 600 906 web www jakkagroup com e mail jakkagroup jakkagroup com JAK KA GROUP CRNA GORA adresa V Crnogorske brigade 3 85347 Igalo Crna Gora telefon 382 0 31 330 285 faks 382 0 31 330 285 mobilni 382 0 69 517 008 web www jakkagroup com e mail technoclima mare t com me ...

Reviews: