JAMA Inverter M
12
LEK
Heating cable (EB14)
Secure the heating
cable (EB14) here
using two cable ties.
JAMA Inverter M
16
LEK
Heating cable (EB14)
Secure the heating cable
(EB14) here using two cable
ties.
Ambient
temperature
sensor
An ambient temperature sensor (Tho-A) is located on the
rear of
JAMA Inverter
.
Communication
JAMA Inverter
can communicate with
JAMA
ind
oor
modules, by connecting the indoor module to the terminal
block X4:4–6 according to the following image:
I
nnemodu
l
X4
GND
GND
B-
B-
A+
A+
GND
B-
A+
AA3
([WHUQDO
JAMA Inverter
;
$$
For connection of indoor module, see relevant manual on
www.kaukora.fi
Addressing
via
cascade
connection
On the communication card (AA23-S2) the communic-
ation address is selected for
JAMA Inverter
to
JAMA
control module. Default has
JAMA Inverter
address
1
. In a
cascade connection all
JAMA Inverter
must have a unique
address. The address is coded in binary.
S2:3
S2:2
S2:1
Address
OFF
OFF
OFF
1
OFF
OFF
On
2
OFF
On
OFF
3
OFF
On
On
4
On
OFF
OFF
5
On
OFF
On
6
On
On
OFF
7
On
On
On
8
29
Chapter
5
|
Electrical
connections
Summary of Contents for M8
Page 1: ...Installer manual LEK LEK LEK J M Inverter M8 M12 M16 Air water heat pump...
Page 2: ......
Page 16: ...LEK DATA XL2 UB1 UB2 XL1 UB3 W1 LEK DATA PF3 PF1 Chapter 3 The heat pump design 14...
Page 47: ...Electrical circuit diagram JAMA Inverter M8 Chapter 9 Technical data 46 Kaukora Oy...
Page 49: ...JAMA Inverter 12 Chapter 9 Technical data 48 Kaukora Oy...
Page 51: ...JAMA Inverter 16 Chapter 9 Technical data 50 Kaukora Oy...
Page 54: ......