Sound pressure levels
JAMA Inverter
is usually placed next to a house wall,
which gives a directed sound distribution that should be
considered. Accordingly, you should always attempt
when positioning to choose the side that faces the least
sound sensitive neighbouring area.
The sound pressure levels are further affected by walls,
bricks, differences in ground level, etc and should
therefore only be seen as guide values.
JAMA Inverter
adjusts the fan speed depending on the
ambient temperature and evaporation temperature.
2 m
6 m
10 m
2 m
LEK
M
16
M
12
M
8
Air-water heat pump
68
57
54
L
W
(A)
Sound power level* According to EN12102 at 7/45 (nominal)
54
43
40
dB(A)
Sound pressure level at 2 m f r e e standing.*
44.5
33.5
30.5
dB(A)
Sound pressure level at 6 m f r e e standing.*
40
29
26
dB(A)
Sound pressure level at 10 m free standing.*
*
Free space.
Chapter 9 |
Technical data
42