SAFETY PRECAUTIONS

Keep it away from children!

This appliance can be used by children aged from 8 years and above if they have been given 

supervision or instruction concerning use of the appliance in a safe way and if they understand the 

hazards involved. Cleaning and user maintenance shall not be made by children unless they are 

aged 8 years and above and supervised. Keep the appliance and its cord out of reach of children 

aged less than 8 years.

• 

Please store the ultrasonic cleaner where it is inaccessible by children.

• 

Danger to children! Danger for death through suffocation! Keep packaging material away from children.

• 

This appliance should not be used by children. Keep the appliance and its cord out of reach of children.

To prevent life-threatening electrical shock, please observe the following:
Danger of electrical shock!  

Do not use while bathing. Never immerse the device or the power cord 

in water or other liquid.

•  Danger of electrical shock! 

 Never touch the power plug with wet hands, especially when inserting or 

removing the plug.

•  Danger of electrical shock! 

 If the unit has fallen into water during operation, do not touch the unit. 

Remove the power plug from the socket first.

•  Danger of electrical shock! 

  Do not spray water or liquid over the device.

• 

Never operate the device unattended.

• 

Follow the manual to operate the device.

• 

Do not use components unapproved by the manufacturer.

• 

When removing the power cord from the socket, grab the power plug not the cord.

• 

To protect the power cord from damage, do not cause it to get caught by things such as cupboard door or 

a chair leg; do not drag across a hot surface.

• 

If there is damage to the power plug, cord, housing, or other parts of the device, do not use the device.

• 

Do not disassemble the device, except by professionals.

• 

If the unit is damaged, non-operational or has fallen into water, take it to a qualified service provider.

• 

Remove the power plug from the socket:
-if malfunction occurs
-before cleaning the device
-if the device is not going to be used for prolonged period
-after each use (recommended)

• 

The installation of an earth leakage circuit breaker with a rated tripping current of no more than 30 mA 

provides further protection against an electrical shock. The installation should only be carried out by a 

trained electrician.

To prevent fire hazards, please observe the following:

• 

Never block the vents on the device. Keep the vents free from lint, hair and other materials.

• 

Do not place the device on a soft surface, such as a bed or a couch, where the vents could be blocked.

• 

Observe the other warnings in the previous section.

• 

If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly 

qualified person in order to avoid a hazard.

•  Always disconnect the unit from the power source when you have finished using the unit.

Summary of Contents for ULTRA 8051

Page 1: ...heater Ceramic heater 100W 65 C temperature limited Multiple circuit protectors When overloaded or improperly used the protectors shut down the power to certain areas to protect the machine Cooling f...

Page 2: ......

Page 3: ...requency vibration The air bubbles burst when in contact with object and dislodge the debris to achieve the cleaning effect Using tap water is sufficient Purified water or distilled water has the same...

Page 4: ...nual to operate the device Do not use components unapproved by the manufacturer When removing the power cord from the socket grab the power plug not the cord To protect the power cord from damage do n...

Page 5: ...let when not in use and before servicing or cleaning To reduce the risk of electrical shock do not put the appliance in water or other liquid Do not place or store appliance where it can fall or be pu...

Page 6: ...4 PRODUCT DETAIL A Top cover B Stainless steel tank C Top casing D Bottom cover E Control panel F Handles G Power socket H Power switch A B C D E F G H Plastic Tray Power Cord...

Page 7: ...uminated the degas function is selected Flashing degassing is underway 6 Normal Cleaning Status Illuminated normal cleaning is underway 7 Heater Status Press Heater button flashes indicating the heate...

Page 8: ...es tools fuel injectors etc BABY ITEMS Toys baby items speech therapy tools etc SILVER COPPER OR BRASS Silverware silver copper or brass decorations etc LAB ITEMS Test tubes beakers flasks etc PCB INK...

Page 9: ...nt Disinfection Rooms Non disposable medical instruments may have blood or organic tissues left after use They need to be removed with ultrasonic cleaners before disinfection 4 Dental Clinics Dental c...

Page 10: ...consuming job Using ultrasonic cleaning with the Enhanced Cleaning method can improve the effectiveness and efficiency 10 Mobile Phone and Electronics Service Shops PCB renewal Non operational electr...

Page 11: ...wellery eyewear watch bands shavers or razors Ultrasonic cleaning can clean the debris in the crevices It is quick and convenient This model has a large tank When cleaning small items the Indirect Cle...

Page 12: ...elp reduce energy absorbtion 2 Aluminum containers Absorbs about 20 of ultrasonic energy 3 Stainless steel containers Absorbs about 8 of ultrasonic energy 10 COMMON CLEANING METHODS Only tap water is...

Page 13: ...then in the tank add water to a level between MIN and MAX and above the area to be cleaned 2 Add special solution SeaClean2 that can remove silver or copper oxidation according to the ratio recommende...

Page 14: ...or 15 minutes Prolonged cleaning time may result in a Loosening of the screws if used b Increasing pre existing cracks c Peeling of coating which was already separated Double press On Off button to st...

Page 15: ...ill be activated after approximately 15 minutes to ensure safety The unit will be disabled until it is repaired Do not run the unit for extended time or continuously The unit is designed with overheat...

Page 16: ...g your unit please call our Returns Department on 44 0 1258 822516 for a RMA Returns Materials Authorisation number Please return your unit in its original packaging along with a covering letter stati...

Reviews: